Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Radiol. bras ; 48(5): 292-297, tab
Article in English | LILACS | ID: lil-764621

ABSTRACT

AbstractObjective:To assess the reduction of estimated radiation dose in abdominal computed tomography following the implementation of new scan protocols on the basis of clinical suspicion and of adjusted images acquisition parameters.Materials and Methods:Retrospective and prospective review of reports on radiation dose from abdominal CT scans performed three months before (group A – 551 studies) and three months after (group B – 788 studies) implementation of new scan protocols proposed as a function of clinical indications. Also, the images acquisition parameters were adjusted to reduce the radiation dose at each scan phase. The groups were compared for mean number of acquisition phases, mean CTDIvol per phase, mean DLP per phase, and mean DLP per scan.Results:A significant reduction was observed for group B as regards all the analyzed aspects, as follows: 33.9%, 25.0%, 27.0% and 52.5%, respectively for number of acquisition phases, CTDIvol per phase, DLP per phase and DLP per scan (p < 0.001).Conclusion:The rational use of abdominal computed tomography scan phases based on the clinical suspicion in conjunction with the adjusted images acquisition parameters allows for a 50% reduction in the radiation dose from abdominal computed tomography scans.


ResumoObjetivo:Quantificar a redução da dose estimada de radiação em exames de tomografia computadorizada de abdome após a implementação de novos protocolos dirigidos para a suspeita clínica e ajuste nos parâmetros técnicos de aquisição.Materiais e Métodos:Foram avaliados, de forma retrospectiva e prospectiva, os relatórios de dose de exames de tomografia computadorizada de abdome realizados três meses antes (grupo A – 511 exames) e três meses após (grupo B – 788 exames) a implementação de novos protocolos de exame propostos em função das indicações clínicas. Contemporaneamente, os parâmetros de aquisição das imagens foram ajustados de modo a reduzir a exposição em cada fase do exame. Os grupos foram comparados quanto ao número médio de fases de aquisição, valores de CTDIvol por fase, DLP por fase e DLP por exame.Resultados:O grupo B apresentou redução significativa em todos os aspectos analisados: número de fases, CTDIvol por fase, DLP por fase e DLP por exame mostraram reduções de 33,9%, 25,0%, 27,0% e 52,5%, respectivamente (p < 0,001).Conclusão:O uso racional das fases de aquisição dirigidas para a suspeita clínica, em conjunto com adequação nos aspectos técnicos, permite reduzir pela metade a dose de radiação por exame de tomografia computadorizada de abdome.

2.
Radiol. bras ; 45(1): 39-45, jan.-fev. 2012. ilus, tab
Article in Portuguese | LILACS | ID: lil-618394

ABSTRACT

Novas técnicas de exames têm sido desenvolvidas com o objetivo de se obter não apenas uma avaliação estrutural, mas também uma análise funcional e metabólica de diversos órgãos e tipos de lesões. Entre estas ferramentas, a perfusão por tomografia computadorizada (PTC) tem despertado o interesse de muitos pesquisadores em estudar a sua aplicabilidade em órgãos e doenças abdominais. Entre estas aplicações podemos citar a avaliação do comportamento biológico de tecidos sadios e doentes, a diferenciação de processos inflamatórios de tumorais e o diagnóstico da recidiva tumoral após terapêuticas minimamente invasivas. A principal característica da PTC reside na sua capacidade de caracterizar comportamentos perfusionais distintos e que traduzem alterações biológicas de determinadas lesões e tecidos doentes. Dessa forma, o nosso objetivo foi realizar uma ampla revisão da literatura, mostrando as principais técnicas e protocolos utilizados nos exames de PTC, as principais indicações, vantagens e desvantagens do método, além de propor um protocolo de exame que possa ser introduzido na rede privada e pública de saúde, com reprodutibilidade e simplicidade de implementação.


New imaging techniques have been developed with the objective of obtaining not only a structural assessment, but also a metabolic and functional analysis of different organs and types of lesions. Among such tools perfusion computed tomography (PCT) has recently aroused the interest of many researchers in studying the applicability of such imaging modality in the evaluation of abdominal organs and diseases. Analysis of the biological behavior of healthy and diseased tissues, differentiation of inflammatory processes from tumors, and diagnosis of tumor recurrence after minimally invasive therapies can be mentioned as applications of such an imaging modality. The main features of PCT are related to its ability to characterize different perfusional behaviors reflecting biological changes of certain lesions and diseased tissues. Thus, the present study was aimed at carrying out a comprehensive literature review, describing the key techniques and protocols utilized in PCT imaging, main clinical applications, advantages and disadvantages of the method, besides proposing an imaging protocol that can be adopted by both private and public health services, with good reproducibility and easy implementation.


Subject(s)
Humans , Abdomen/pathology , Diagnostic Techniques and Procedures , Perfusion Imaging/methods , Reproducibility of Results , Sensitivity and Specificity , Multidetector Computed Tomography , Contrast Media/administration & dosage
3.
Radiol. bras ; 40(6): 383-387, nov.-dez. 2007. ilus, tab
Article in English, Portuguese | LILACS | ID: lil-471997

ABSTRACT

OBJETIVO: Medir a reprodutibilidade da tomografia computadorizada sem e com contraste na avaliação da gravidade da pancreatite aguda. MATERIAIS E MÉTODOS: Cinqüenta e um exames de tomografia computadorizada abdominal sem e com contraste de pacientes com pancreatite aguda foram analisados por dois radiologistas (observadores 1 e 2). Calculamos o índice morfológico pela tomografia computadorizada sem e com contraste, separadamente, e o índice de gravidade da tomografia computadorizada para pancreatite aguda. Medimos a reprodutibilidade intra- e interobservador da tomografia computadorizada através do índice kappa (kapa). RESULTADOS: Para a concordância interobservador obtivemos kapa de 0,666, 0,705, 0,648, 0,547 e 0,631 para índice morfológico sem e com contraste, presença de necrose pancreática, extensão da necrose pancreática e índice de gravidade da tomografia computadorizada, respectivamente. Para a concordância intra-observador dos observadores 1 e 2 obtivemos, respectivamente, kapa de 0,796 e 0,732 para o índice morfológico sem contraste; 0,725 e 0,802 para o índice morfológico com contraste; 0,674 e 0,849 para a presença de necrose pancreática; 0,606 e 0,770 para a extensão da necrose pancreática; e 0,801 e 0,687 para o índice de gravidade da tomografia computadorizada. CONCLUSÃO: O estadiamento da pancreatite aguda pela tomografia computadorizada por meio do índice morfológico e do índice de gravidade da tomografia computadorizada é um método bastante reprodutível. O não-uso do contraste não afeta a reprodutibilidade da tomografia computadorizada para o cálculo do índice morfológico.


OBJECTIVE: To evaluate the reproducibility of unenhanced and contrast-enhanced computed tomography in the assessment of patients with acute pancreatitis. MATERIALS AND METHODS: Fifty-one unenhanced and contrast-enhanced abdominal computed tomography studies of patients with acute pancreatitis were blindly reviewed by two radiologists (observers 1 and 2). The morphological index was separately calculated for unenhanced and contrast-enhanced computed tomography and the disease severity index was established. Intraobserver and interobserver reproducibility of computed tomography was measured by means of the kappa index (kappa). RESULTS: Interobserver agreement was kappa = 0.666, 0.705, 0.648, 0.547 and 0.631, respectively for unenhanced and contrast-enhanced morphological index, presence of pancreatic necrosis, pancreatic necrosis extension, and disease severity index. Intraobserver agreement (observers 1 and 2, respectively) was kappa = 0.796 and 0.732 for unenhanced morphological index; kappa = 0.725 and 0.802 for contrast-enhanced morphological index; kappa = 0.674 and 0.849 for presence of pancreatic necrosis; kappa = 0.606 and 0.770 for pancreatic necrosis extension; and kappa = 0.801 and 0.687 for disease severity index at computed tomography. CONCLUSION: Computed tomography for determination of morphological index and disease severity index in the staging of acute pancreatitis is a quite reproducible method. The absence of contrast-enhancement does not affect the computed tomography morphological index reproducibility.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged, 80 and over , Contrast Media , Pancreatitis/diagnosis , Pancreatitis/therapy , Reproducibility of Results , Tomography, Spiral Computed/methods , Prognosis , Prospective Studies , Severity of Illness Index , Tomography, X-Ray Computed
4.
São Paulo med. j ; 125(2): 102-107, Mar. 2007. graf, tab, ilus
Article in English | LILACS | ID: lil-454752

ABSTRACT

CONTEXT AND OBJECTIVE: Recent studies have shown noncontrast computed tomography (NCT) to be more effective than ultrasound (US) for imaging acute ureterolithiasis. However, to our knowledge, there are few studies directly comparing these techniques in an emergency teaching hospital setting. The objectives of this study were to compare the diagnostic accuracy of US and NCT performed by senior radiology residents for diagnosing acute ureterolithiasis; and to assess interobserver agreement on tomography interpretations by residents and experienced abdominal radiologists. DESIGN AND SETTING: Prospective study of 52 consecutive patients, who underwent both US and NCT within an interval of eight hours, at Hospital São Paulo. METHODS: US scans were performed by senior residents and read by experienced radiologists. NCT scan images were read by senior residents, and subsequently by three abdominal radiologists. The interobserver variability was assessed using the kappa statistic. RESULTS: Ureteral calculi were found in 40 out of 52 patients (77 percent). US presented sensitivity of 22 percent and specificity of 100 percent. When collecting system dilatation was associated, US demonstrated 73 percent sensitivity, 82 percent specificity. The interobserver agreement in NCT analysis was very high with regard to identification of calculi, collecting system dilatation and stranding of perinephric fat. CONCLUSIONS: US has limited value for identifying ureteral calculi in comparison with NCT, even when collecting system dilatation is present. Residents and abdominal radiologists demonstrated excellent agreement rates for ureteral calculi, identification of collecting system dilatation and stranding of perinephric fat on NCT.


CONTEXTO E OBJETIVO: Estudos atuais demonstram que a tomografia computadorizada helicoidal sem contraste (TC) apresenta maior acurácia do que a ultra-sonografia (US) no diagnóstico da ureterolitíase aguda, porém, poucos estudos a esse respeito foram realizados em atendimento radiológico de urgência de hospital universitário. Nossos objetivos foram comparar a sensibilidade diagnóstica da US com a TC realizadas por residentes no diagnóstico de ureterolitíase aguda e comparar a análise da TC interpretada por residentes e radiologistas experientes. TIPO DE ESTUDO E LOCAL: Estudo prospectivo de 52 pacientes com cólica renal aguda, que foram submetidos a exame de US seguido de TC em período máximo de oito horas no Hospital São Paulo. MÉTODOS: Os exames de US foram realizados por médicos residentes e conferidos pelos preceptores, já os de TC foram analisados por outro residente e posteriormente analisados por três radiologistas independentes. RESULTADOS: Nos 52 pacientes analisados foram encontrados 40 cálculos ureterais na TC (77 por cento). A US apresentou uma sensibilidade de 22 por cento e especificidade de 100 por cento, que aumentou para 73 por cento e 82 por cento respectivamente, quando se associou a identificação da dilatação do sistema coletor. A TC analisada pelo residente e pelos radiologistas apresentou uma excelente correlação para identificação do cálculo ureteral, para heterogeneidade da gordura peri-renal e para dilatação do sistema coletor. CONCLUSÕES: A US realizada pelos residentes tem menor sensibilidade no diagnóstico da litíase ureteral, quando comparada à TC, mesmo quando associada à presença de dilatação do sistema coletor. Residentes e radiologistas especialistas apresentaram excelente concordância no diagnóstico de litíase ureteral.


Subject(s)
Humans , Observer Variation , Tomography, Spiral Computed/standards , Ureteral Calculi , Ureteral Calculi , Acute Disease , Epidemiologic Methods , Hospitals, Teaching , Internship and Residency , Physicians , Professional Competence , Radiography, Abdominal , Radiology
5.
Radiol. bras ; 39(5): 341-344, set.-out. 2006. ilus, tab
Article in Portuguese | LILACS | ID: lil-446726

ABSTRACT

OBJETIVO: Avaliar a reprodutibilidade da tomografia computadorizada sem contraste na avaliação da litíase ureteral e os sinais secundários de obstrução do sistema coletor em pacientes com cólica renal aguda. MATERIAIS E MÉTODOS: Estudo prospectivo de 52 pacientes com diagnóstico clínico de cólica renal aguda submetidos a exame de tomografia computadorizada de abdome sem contraste. Os exames foram realizados com técnica helicoidal e posteriormente analisados por três observadores independentes, com a concordância interobservador avaliada pelo método estatístico kappa (kapa). Foram analisados os parâmetros: a) presença, localização e mensuração dos cálculos ureterais; b) dilatação do sistema coletor intra-renal; c) heterogeneidade da gordura perirrenal; d) dilatação ureteral; e) edema da parede ureteral (sinal do halo). RESULTADOS: Foram encontrados 40 cálculos ureterais na tomografia computadorizada (77 por cento). A concordância interobservador para a identificação do cálculo ureteral e da dilatação ureteral foi quase perfeita (kapa = 0,89 e kapa = 0,87, respectivamente), substancial para dilatação do sistema coletor intra-renal (kapa = 0,77) e moderada para heterogeneidade da gordura perirrenal e para edema da parede ureteral (kapa = 0,55 e kapa = 0,56, respectivamente). CONCLUSÃO: A tomografia computadorizada de abdome sem contraste apresenta elevada reprodutibilidade na avaliação da litíase ureteral e dos sinais secundários de obstrução do sistema coletor.


OBJECTIVE: To evaluate the interobserver agreement on non-contrast computed tomography interpretation by a group of experienced abdominal radiologists, for the study of urolithiasis in patients presenting acute flank pain. MATERIALS AND METHODS: Prospective study of 52 patients submitted to non-contrast enhanced helical computed tomography. The images were subsequently analyzed by three independent observers, with the interobserver agreement assessed by means of the kappa (kappa) statistical method. The following parameters were analyzed: a) presence, localization and measurement of ureteral calculi; b) intrarenal calyceal system dilatation; c) perirenal fat heterogeneity; d) ureteral dilatation; e) ureteral wall edema (halo sign). RESULTS: Ureteral calculi were found in 40 of 52 patients (77 percent). The interobserver agreement was almost perfect as regards identification of ureteral calculi (kappa = 0.89) and ureteral dilatation (kappa = 0.87), substantial for calyceal system dilatation (kappa = 0.77), and moderate for perirenal fat heterogeneity (kappa = 0.55) and ureteral wall edema (kappa = 0.56). CONCLUSION: Non-contrast-enhanced abdominal computed tomography presents high reproducibility in the evaluation of urolithiasis and secondary signs of the calyceal system obstruction.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Ureteral Calculi/complications , Flank Pain/etiology , Lithiasis/diagnosis , Ureteral Calculi , Radiography, Abdominal , Reproducibility of Results , Tomography, X-Ray Computed
6.
Radiol. bras ; 33(3): 175-8, maio-jun. 2000. ilus
Article in Portuguese | LILACS | ID: lil-280185

ABSTRACT

Os autores descrevem um caso incumum de metástase orbitária de tumor renal envolvendo a musculatura extrínseca ocular bilateralmente, apresentando-se como manifestaçäo inicial do tumor original. Säo analisados os aspectos tomográficos da lesäo, sendo ressaltada a importância desse diagnóstico como diferencial nas lesões orbitárias.


Subject(s)
Humans , Male , Female , Adenocarcinoma/complications , Orbital Diseases/complications , Kidney/physiopathology , Diagnostic Imaging
7.
Acta cir. bras ; 5(4): 154-9, out.-dez. 1990. tab
Article in Portuguese | LILACS | ID: lil-92938

ABSTRACT

Os autores se propöem a estudar o comportamento de um segmento de colo distal interposto no trajeto do intestino delgado ressecado, em relaçäo à absorçäo de glicose, comparando-o a um segmento semelhante de colo mantido em sua posiçäo normal. Utilizando o método de passagens rápidas e sucessivas de uma soluçäo de glicose de concentraçäo conhecida por um segmento de colo distal interposto após ressecçäo de 8% do comprimento do jejuno-íleo e por um segmento semelhante de colo distal em sua posiçäo normal no mesmo animal, logrou-se comparar as curvas de absorçäo de glicose entre estes dois segmentos e relacioná-las com curvas padräo de absorçäo de glicose do intestino delgado e do colo de ratos. Os resultados mostraram que o segmento de colo interposto absorve glicose em maior quantidade quando comparado ao colo distal mantido em sua posiçäo normal


Subject(s)
Rats , Animals , Female , Intestinal Absorption/physiology , Colon/metabolism , Glucose/metabolism , Short Bowel Syndrome/etiology , Ileum/surgery , Ileum/metabolism , Jejunum/metabolism , Jejunum/surgery , Rats, Inbred Strains
SELECTION OF CITATIONS
SEARCH DETAIL